| Item | Parameter |
|---|---|
| Equipment Name | High Vacuum Atmosphere Box Furnace (with Chiller Cooling System) |
| Power Supply | 380 V, 50 Hz |
| Max Working Temperature | 1400℃ |
| Recommended Long-term Working Temperature | 1350℃ |
| Temperature Adjustment Range | Room temperature ~ 1400℃ |
| Chamber Size (W × D × H) | 600 × 400 × 400 mm |
| Heating Element | Graphite Rod |
| Thermocouple | Type S Thermocouple |
| Temperature Control Accuracy | ±1℃ (integrated control, no overshoot) |
| Heating Rate | Adjustable from 1℃/h to 30℃/min (non-linear, recommended: 10–20℃/min) |
| Working Gas | Hydrogen, Nitrogen, Argon, Carbon Monoxide, Oxygen, etc. |
| Vacuum Degree | -0.1 MPa (gauge pressure) |
| Gas Circuit Valve | Stainless Steel |
| Gas Flowmeter | Two float flowmeters (digital mass flowmeter optional) |